Particle Size Distribution in Cleaning Trials: Number vs Volume

A cleaning-trial discussion includes two summaries of the same particle population: one says the small group is about 89%, the other says 50%. Before treating this as a disagreement, ask what each percentage measures. Our hypothetical example shows the question to resolve.

Hypothetical spheres: eight with diameter d and one with diameter 2d, compared by number and volume.

Original arithmetic illustration of one unchanged population. These percentages are composition fractions, not cleaning-removal results.

Identify what the distribution weighs

The public terminology in ISO 19430:2024, clause 3.5 describes particle size distribution in terms of particle quantity across sizes. The quantity may be based on number, mass or volume. Here we compare number and volume only.

ISO 19430 concerns particle tracking analysis in liquid dispersions. We use its terminology; it is not a dry-film cleaning acceptance standard.

Work through one nine-particle population

Imagine eight spheres with diameter d and one sphere with diameter 2d. Let V be the volume of one small sphere. A sphere's volume is πd3/6, so the larger sphere has volume 8V. The eight small spheres together also occupy 8V.

GroupCountGroup volumeFraction by numberFraction by volume
Small: diameter d88V8/9 ≈ 88.9%8/16 = 50%
Large: diameter 2d18V1/9 ≈ 11.1%8/16 = 50%

Nothing has been added, removed or cleaned between the two calculations. Only the weighting changes. The model has no real size unit and does not represent dust sampled from a production line.

Keep the measurement method with the result

In its laser-diffraction discussion, NIST's Particle Size Characterization guide (pages 110–111) describes volume-based output and number or surface-area representations derived from it. It also warns that departures from spherical shape can introduce error or bias. This is a method-specific discussion, not a statement that every particle instrument starts with volume.

Our exact sphere arithmetic is therefore not a conversion recipe for an irregular-dust report. Ask the laboratory which basis was measured or derived and which assumptions the reported conversion uses.

Resolve the comparison before reviewing a cleaner

Return to the invented summaries. Label the first “small group: approximately 89% by number” and the second “small group: 50% by volume.” Both now describe our model correctly. Neither is a before-and-after removal percentage.

For a real proposal, request the size interval, reporting basis and method beside each percentage. Have the trial team identify which result addresses the agreed cleaning requirement. Do not rank two cleaners from unlike population fractions or silently rename a volume fraction as a particle-count fraction.

For the separate questions of inspected surface area and image-size descriptors, see reading a surface particle inspection report.

Bring the particle report to your cleaning review

Share the material, process stage and original report headings when discussing a dry-cleaning trial. Our team can review the application and the information needed for equipment selection. This example does not establish removal performance for a Shidike cleaner.

Explore Cleaning Machines →Discuss your cleaning application →